-40%
Beckett 7505A0000U 7505A GeniSys Primary Control 120V Oil Burner
$ 36.4
- Description
- Size Guide
Description
BECKETT GENISYS ADVANCED OIL BURNER CONTROLBECKETT 7505A0000U
*LOCKOUT TIME: 15 SECONDS
*VALVE-ON DELAY TIME: N/A
*MOTOR OFF DELAY TIME: N/A
Valve-on delay and motor-off delay timings on all models are programmable with Beckett snap-in programming display. Other factory set timings are available. Contact Beckett for alternate timings.
*FOR CONTROLS WITH ALARM CONTACTS YOU ATTACH THE ALARM CONTACT MODULE WHICH IS SOLD SEPERATELY
Product Description
The Beckett GeniSys™ Advanced Burner Control is a 120 Vac primary safety control for residential and light commercial oil burners used in boiler, furnace, and water heater applications. The GeniSys is used with a suitable cad cell fl ame sensor to control the oil burner motor, igniter, and optional solenoid valve. It has 24 Vac thermostat inputs compatible with both on/off and power stealing thermostats. It can provide interrupted or intermittent duty ignition, and has a 15-second lockout time.
Features & Benefits
*Thermostat and boiler control compatible
*Programmable valve-on delay and motor-off delay
*Three indicator lights for system monitoring and diagnostics
*Two communication ports for adding alarm contacts, programming display, and/or future wireless communications
*Welded relay protection with redundant motor relays
*Limited reset and limited recycle
*Sleek, modern design
*Cad cell resistance indicator
*Technician Pump Prime mode
Electrical Ratings
Inputs
Voltage: 102 to 132 Vac
Current: 100 mA plus burner motor, igniter, and valve loads
Frequency: 60 Hz
Outputs
Motor: 120 Vac, 10 full load amps (FLA), 60 locked rotor amps (LRA)
Note – Reduce motor FLA rating by igniter load
Igniter: 120 Vac, 3 A @ 0.7 PF min
Solenoid Valve: 120 Vac, 1 A @ 0.7 PF min
Thermostat Anticipator Current: 0.1 mA
Thermostat Voltage: 24 Vac
Environmental Ratings
Storage and Operating Ambient Temperature: -40°F to +150°F (-40°C to +65°C)
Moisture: 5 to 95% RH, non-condensing and non-crystallizing
Approvals
REPLACES: HONEYWELL R7184A, R8184G
NOTE
*THIS CONTROL IS A 15 SECOND LOCKOUT MAKING IT SAFER THEN THE 45 AND 30 SECOND CONTROLS
*FOR CONTROLS WITH ALARM CONTACTS YOU ATTACH THE ALARM CONTACT MODULE WHICH IS SOLD SEPERATELY
ALSO REPLACES CARLIN: 48245, 40200 42230, 42230-02S, 42230-02A, 4223002A 50200
Beckett snap-in alarm module required for direct replacement of the Carlin 502001
Please note some of the items require professional knowledge and skills to handle or installed. Thomas New Parts is not responsible for any damage or injuries resulted from mishandling of professional products. All HVACR equipment should be serviced/installed by certified professionals only. Please let us know if you have any concerns or questions.
Before Opening a Return Request or eBay Resolution Case
Please contact us through the eBay message center and let us know how we can help!
Once a case is opened it is difficult to correct your problem!